  document no. eeu-1476a (o. d. no. eeu-947a) date published may 1995 p printed in japan 1994 EP-78024 emulation probe EP-78024cw-r EP-78024gf-r 1994, 1995
the information in this document is subject to change without notice. no part of this document may be copied or reproduced in any form or by any means without the prior written consent of nec corporation. nec corporation assumes no responsibility for any errors which may appear in this document. nec corporation does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other liability arising from use of such device. no license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of nec corporation or of others.
major revisions in this edition page contents throughout combined with EP-78024gf-r users manual (eeu-1477) p.6 addition of caution to 2.1 (1) connecting emulation board and connector board p.10 addition of description and caution on sense clip to 2.1 (4) connecting external sense clip p.13 correction of figure 2-6. removing EP-78024cw-r p.14 correction of figure 2-7. removing EP-78024gf-r the mark h shows revised points.
introduction readers : this manual is intended for users who wish to debug microcontrollers using an in-circuit emulator and the EP-78024. for the combination of the emulation probe and target device, refer to the documents of the respective devices and the selection guides of the development tools. purpose : this manual describes how to connect the EP-78024 to an in-circuit emulator. organization : this manual contains the following information: general connection how to read this manual : before reading this manual, read the manuals related to the in-circuit emulator to be used and familiarize yourself with the organization and functions of the debugging system. ? to understand the overall functions and connections of the EP-78024 ? read this manual in the order of the table of contents. ? to understand the operating environment and organization ? read chapter 1 general . ? to understand connection ? read chapter 2 connection . unless otherwise specified, the EP-78024cw-r and EP-78024gf-r are referred to as EP-78024. read EP-78024 as EP-78024cw-r if you use this manual as the manual for the EP-78024cw-r. if you use this manual as that for the EP-78024gf-r, read EP-78024 as EP-78024gf-r. notations used in this manual note : footnote caution : important information remark : supplement h h
unpacking carton box : the carton box of the EP-78024 contains the following items. confirm that all the items are contained. if any item is missing or damaged, consult nec. qty ? emulation probe 1 ? connector board 1 ? users manual (this manual) 1 ? mounting screw 2 ? used to connect the emulation probe and in-circuit emulator. ? conversion socket 1 ? used to connect the emulation probe and target system. (ev-9200g-64 is supplied with the EP-78024gf-r). <> emulation probe connector board conversion socket EP-78024gf-r 64gf connector ev-9200g-64 EP-78024cw-r 64cw connector not supplied h h
contents chapter 1 general ............................................................................................................... .............1 1.1 operating environment ..............................................................................................1 1.2 organization .............................................................................................................. ..2 chapter 2 connection ............................................................................................................ .........5 2.1 connecting in-circuit emulator and target system ................................................5 2.2 turning on/off power ..............................................................................................12 2.3 removing emulation probe from target system ..................................................13 appendix a pin number of each emulation probe ................................................................15 a.1 64-pin cw and 64-pin gf emulation probes ..........................................................15 appendix b socket drawing and footprint of conversion socket .............................17 b.1 ev-9200g-64 ..............................................................................................................1 7 appendix c revision history ..................................................................................................... ....19 C i C
list of figures figure no. title, page figure 1-1. operating environment ............................................................................................... ............................1 figure 1-2. EP-78024 and connector board ........................................................................................ ......................3 figure 2-1. connecting ie-78044-r-em and connector board ........................................................................ ..........6 figure 2-2. example of connecting ie-78000-r and emulation probe ................................................................ ......7 figure 2-3. connecting EP-78024cw-r and target system ........................................................................... .......... 8 figure 2-4. connecting EP-78024gf-r and target system ........................................................................... ...........9 figure 2-5. connecting external sense clip ...................................................................................... ......................11 figure 2-6. removing EP-78024cw-r ............................................................................................... ..................... 13 figure 2-7. removing EP-78024gf-r ............................................................................................... ......................14 figure b-1. socket drawing of ev-9200g-64 (reference) ........................................................................... ............17 figure b-2. footprint of ev-9200g-64 (reference) ................................................................................ ..................18 C ii C
1 chapter 1 general chapter 1 general this chapter describes the outline of the EP-78024. 1.1 operating environment the EP-78024 is a probe set that connects an in-circuit emulator and a target system. by connecting the in- circuit emulator and target system with the EP-78024, the debugging environment of a microcontroller is established and the hardware and software of the target system can be debugged. for details of connection, refer to chapter 2 connection . figure 1-1. operating environment ? connecting in-circuit emulator and target system { in-circuit emulator target system emulation probe connector board emulation board EP-78024
2 chapter 1 general 1.2 organization the EP-78024 consists of an emulation probe and a connector board. (1) emulation probe the emulation probe consists of the following three parts: n n probe connects the in-circuit emulator and target system. ? EP-78024cw-r : 64-pin cw probe ? EP-78024gf-r : 64-pin gf probe n n ground clip connected to gnd of the target system to make the gnd potential of the in-circuit emulator the same as that of the target system and thereby improve the resistance to static electricity and the noise immunity of the system. n n external sense clip consists of eight sense clips which are used to check the voltage level of the pins of the ic mounted on the target system. (2) connector board the connector board connects the pins on the emulation board which output signals to the emulation probe, and is connected to the connector note on the emulation board. note the location on the emulation board at which the connector board is to be connected differs depending on the emulation board. refer to the users manuals of the in-circuit emulator or emulation board.
3 chapter 1 general figure 1-2. EP-78024 and connector board (1/2) EP-78024cw-r EP-78024gf-r
4 chapter 1 general figure 1-2. EP-78024 and connector board (2/2) connector board
5 chapter 2 connection chapter 2 connection this chapter describes how to connect the EP-78024, turn on/off the power, and remove the emulation probe from the target system. 2.1 connecting in-circuit emulator and target system connect the in-circuit emulator and target system following these steps: (1) connect the emulation board and connector board. note that the board to be connected differs depending on the in-circuit emulator used. (2) connect the in-circuit emulator and emulation probe. (3) connect the emulation probe and target system. (4) connect the external sense clip (when the external sense clip is used). (5) turn on the power. each step, (1) to (5), is described in detail next.
6 chapter 2 connection (1) connecting emulation board and connector board <1> turn off the power to the in-circuit emulator. <2> connect the emulation board and connector board. <3> install the emulation board (with the connector board connected) to the in-circuit emulator. caution if the connector board is inserted to a wrong connector on the emulation board, the in-circuit emulator may be damaged. in the following description, it is assumed that the emulation board ie-78044-r-em is used. <1> turn off the power to the ie-78000-r. <2> connect cn3 and cn4 of the connector board to cn3 and cn4 of the ie-78044-r-em. <3> remove the screws (at six places) from the top of the ie-78000-r, and open the lid. <4> pull the card pullers at both edges of the ie-78000-r-bk in the in-circuit emulator toward you to pull out the board. <5> secure the ie-78044-r-em and ie-78000-r-bk with screws. <6> return the ie-78000-r-bk, onto which the ie-78044-r-em has been mounted, to the original position in the ie-78000-r. figure 2-1. connecting ie-78044-r-em and connector board h connector board emulation board (ie-78044-r-em) cn3 cn3 cn4 cn4 remark the shape of the emulation board differs depending on the model, but connection between the emulation board and connector board is the same as shown in figure 2-1. for details of how to mount the board to the in-circuit emulator, refer to the users manual of the in-circuit emulator.
7 chapter 2 connection (2) connecting in-circuit emulator and emulation probe <1> connect the emulation probe to the emulation probe connecting din connector on the top of the in-circuit emulator. <2> after connection, be sure to secure the emulation probe and in-circuit emulator with screws. figure 2-2. example of connecting ie-78000-r and emulation probe mounting screws emulation probe ie-78000-r (cnn note ) note this figure shows the case where the ie-78044-r-em is used as the emulation board. the connector to be connected differs depending on the emulation board. refer to the users manual of the in-circuit emulator or emulation board.
8 chapter 2 connection (3) connecting emulation probe and target system connect the emulation probe and target system in the following sequence: cautions 1. before connecting the emulation probe to the target system, be sure to connect the ground clip first. otherwise, the in-circuit emulator may be damaged by static electricity. 2. be sure to connect the pins in the correct direction. if they are connected in the wrong direction, the in-circuit emulator may be damaged. <1> turn off the power to the target system. <2> solder the conversion socket to the target system. use the following socket: ? EP-78024cw-r : shrink dip socket commercially available ? EP-78024gf-r : socket supplied as an accessory (ev-9200g-64) <3> connect the ground clip of the emulation probe to the ground (gnd) of the target system. <4> connect the emulation probe to the target system so that the position of the tip of the emulation probe comes to the position of pin 1 of the conversion socket solder onto the target system in step <2> above. figure 2-3. connecting EP-78024cw-r and target system 1 64 32 33 in-circuit emulator external sense clip ground clip 64-pin cw shrink dip socket (commercially available) target system
9 chapter 2 connection figure 2-4. connecting EP-78024gf-r and target system 52 51 33 32 19 64 20 1 1 in-circuit emulator external sense clip ground clip 64-pin gf conversion socket (ev-9200g-64) target system
10 chapter 2 connection (4) connecting external sense clip (when external sense clip is used) the emulation probe is provided with an external sense clip that consists of eight clips and can trace the signals of the hardware on the target system in real time. because the external sense clip is directly connected to the input buffer hct244 in the in-circuit emulator, its input is ttl level. usually, the eight external sense clips are used as input signal lines. depending on the setting of the out command of the in-circuit emulator, however, the signal line of external sense clip 1 can be used to output a trigger signal to an external device when an event occurs (for details, refer to the manual of the in-circuit emulator). cautions 1. connect the external sense clips to the signal lines of ttl level. if they are connected to the other signal lines, the high and low levels of signals cannot be accurately detected. in addition, the sensors of the in-circuit emulator may be damaged depending on the voltage level. 2. when using external sense clip 1 as a trigger output line, make sure that external sense clip 1 is not connected to a signal output line. otherwise, malfunction may occur. h h
11 chapter 2 connection connect the external sense clip in the following sequence: <1> turn off the power to the target system and then to the in-circuit emulator. <2> mount a commercially available ic clip to the ic on the target system to be traced. <3> connect the external sense clip to the ic clip. <4> turn on the power to the in-circuit emulator and then to the target system. figure 2-5. connecting external sense clip ic ic clip target system external sense clip remark to connect the external sense clip, use an ic clip whenever possible, to prevent bad contact and improve operability.
12 chapter 2 connection 2.2 turning on/off power after connecting the emulation probe and target system, turn on the power. be sure to turn on or off the power in the sequence described below. caution be sure to turn on/off the power in the correct sequence; otherwise, the in-circuit emulator may be damaged. (1) power-on sequence <1> turn on power to the in-circuit emulator. <2> turn on power to the target system. (2) power-off sequence <1> turn off power to the target system. <2> turn off power to the in-circuit emulator.
13 chapter 2 connection 2.3 removing emulation probe from target system remove the emulation probe from the target system in the following sequence: (a) with EP-78024cw-r <1> turn off power to the target system. <2> turn off power to the in-circuit emulator. <3> pull up the lever on the shrink dip socket. <4> pull up the bracket at the tip of the emulation probe at right angles to the target system, to remove the emulation probe from the shrink dip socket. figure 2-6. removing EP-78024cw-r h target system lever shrink dip socket bracket
14 chapter 2 connection (b) with EP-78024gf-r <1> turn off power to the target system. <2> turn off power to the in-circuit emulator. <3> pull up the bracket at the tip of the emulation probe at right angles to the target system, to remove the emulation probe from the conversion socket. figure 2-7. removing EP-78024gf-r h target system conversion socket bracket
15 appendix a pin number of each emulation probe a.1 64-pin cw and 64-pin gf emulation probes cnn emulation cnn emulation cnn emulation cnn emulation pin no. probe pin no. probe pin no. probe pin no. probe 1 gnd 25 15 49 39 73 63 2 26 16 50 40 74 64 3 ext0 27 17 51 41 75 nc 4 ext1 28 18 52 42 76 5 ext2 29 19 53 43 77 6 ext3 30 20 54 44 78 7 ext4 31 21 55 45 79 8 ext5 32 22 56 46 80 9 ext6 33 23 57 47 81 10 ext7 34 24 58 48 82 11 1 35 25 59 49 83 12 2 36 26 60 50 84 13 3 37 27 61 51 85 14 4 38 28 62 52 86 15 5 39 29 63 53 87 16 6 40 30 64 54 88 17 7 41 31 65 55 89 18 8 42 32 66 56 90 19 9 43 33 67 57 91 20 10 44 34 68 58 92 21 11 45 35 69 59 93 22 12 46 36 70 60 94 23 13 47 37 71 61 95 gnd 24 14 48 38 72 62 96 remarks 1. cnn: connector connecting the emulation probe. in the above table, it is assumed that the emulation board ie-78044-r-em is used. the value of n differs depending on the emulation board connected. for details, refer to the users manual of the emulation board or in-circuit emulator. 2. the meanings of the symbols and numbers in the column emulation probe are as follows: gnd : ground clip (gnd) ext0-ext7 : external sense clip 1 to 8 1-64 : emulation probe pin number nc : no connection
16 [memo]
17 appendix b socket drawing and footprint of conversion socket b.1 ev-9200g-64 figure b-1. socket drawing of ev-9200g-64 (reference) a g e 1 no.1 pin index f b c n o p m l t s j i r d u q ev-9200g-64 k h ev-9200g-64-g0 item millimeters inches a b c d e f g h i j k l m o n p q r s t u 25.0 20.30 4.0 14.45 19.0 4-c 2.8 0.8 11.0 22.0 24.7 5.0 16.2 18.9 8.0 7.8 2.5 2.0 1.35 0.35 0.1 2.3 1.5 0.984 0.799 0.157 0.569 0.748 4-c 0.11 0.031 0.433 0.866 0.972 0.197 0.638 0.744 0.315 0.307 0.098 0.079 0.053 0.014 0.091 0.059 +0.004 ?.005 f f f f
18 figure b-2. footprint of ev-9200g-64 (reference) appendix b socket drawing and footprint of conversion socket a f d e b g j k c l m h i 0.039 0.709=0.709 0.039 0.472=0.472 ev-9200g-64-p0 item millimeters inches a b c d e f g h i j k l m 25.7 21.0 15.2 19.9 11.00 0.08 5.50 0.03 5.00 0.08 2.50 0.03 0.6 0.02 2.36 0.03 1.57 0.03 1.012 0.827 0.598 0.783 0.433 0.217 0.197 0.098 0.024 0.093 0.062 1.0 0.02 18=18.0 0.05 1.0 0.02 12=12.0 0.05 f f +0.002 ?.001 +0.002 ?.003 +0.002 ?.001 +0.003 ?.002 +0.004 ?.003 +0.001 ?.002 +0.003 ?.004 +0.002 ?.001 +0.001 ?.002 +0.001 ?.002 f f +0.001 ?.002 dimensions of mount pad for ev-9200 and that for target device (qfp) may be different in some parts. for the recommended mount pad dimensions for qfp, refer to "semiconductor device mounting technology manual" (iei-1207). caution
19 appendix c revision history the following table shows the revision history of this manual. the place column indicates the chapter of each edition that was revised. edition revision place 2nd edition combined with EP-78024gf-r users manual (eeu-1477) throughout addition of caution to description on connection between emulation board and chapter 2 connector board connection addition of description and caution to description on connection of external sense clip correction of figure illustrating removal of emulation probe
20 [memo]


▲Up To Search▲   

 
Price & Availability of EP-78024

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X